Glycol Chiller | 5 Horsepower | Indoor Unit

Glycol Chiller | 5 Horsepower | Indoor Unit

BGD-5A
  • Air-cooled glycol chillers are purpose built for the unique requirements of breweries and distilleries.
  • Set up for low temperature operation and high flow, the glycol chiller is designed to circulate glycol through fermentation tanks, conditioning tanks, wort chiller and storage rooms.
  • Temperature control is achieved by using a “tailor made” microprocessor control instrument designed and manufactured exclusively for this glycol chiller.
  • This glycol chiller is designed to be located indoors.
  • The electrical cabinet is NEMA 1 rated.
  • A rugged frame supports the the components in these glycol chillers.
  • Shipment is made via enclosed trailer.
  • This glycol chiller is designed for indoor installation.
Loading pricing...
Immediate Pricing
30,512Cooling Capacity BTU
5Compressor HP
12Gallons/Minute (GPM)
  • Specifications
  • Features
  • Options
  • Control Instrument
  • Support Documents

Specifications

Cooling Capacity
Glycol Temperature @ 25°F: 30512 BTU/hr
Glycol Temperature @ 50°F: 60000 BTU/hr
Compressor
Horsepower: 5
Type: Digital Scroll
Air-Cooled Condenser
Type: Fan
CFM: 5000
Ambient: 90°F
Evaporator
Type: Brazed Plate
Refrigerant
Type: R-454B
Classification: A2L (Lower Toxicity, Mildly Flammable)
Low Global Warming Potential (GWP)
Process Pump
Horsepower: 2
Flow: 12 GPM
Reservoir Capacity
Capacity: 25 Gallons
Lid: Standard
Process Connections
To Process: 1¼"
From Process: 1¼"
Full Load Amperage
230/1/60: 56
230/3/60: 34
460/3/60: 18
575/3/60: 14
Dimensions
Height: 60"
Width: 34"
Depth: 40"
Weight
Shipping: 800 LBS
Specification Notes:
  1. Since product innovation and improvement is our constant goal, all features and specifications are subject to change without notice or liability. Selection of certain optional features may change listed specifications.
  2. Cooling capacity: Rated tons at 12,000 BTU/hr/ton. The minimum recommended operating temperature when no glycol is used is 48°F.
  3. Ambient conditions: Loss of capacity and/or difficulty operating may occur at higher ambient temperatures. The minimum recommended ambient temperature is 60°F.

Features

Refrigerant Circuit

  • R-454B refrigerant
  • Digital scroll compressor
  • Energy efficient capacity control from 20% – 100%
  • Air-Cooled condenser
  • Internal to Unit
  • Fan induced air flow
  • Brazed plate evaporator
  • Stainless steel plates
  • Copper brazing material
  • Refrigerant sight glass with moisture indicator
  • Filter-drier
  • Thermostatic expansion valve
  • Liquid line solenoid valve

Electrical

  • Nema 1 control cabinet
  • Branch Circuit Fusing
  • Process pump motor starter
  • Compressor contactor
  • Power entry terminal block

Coolant Circuit

  • High flow centrifugal pump
  • Internal Reservoir
  • Insulated
  • Non-ferrous polyethylene construction
  • Reservoir lid is standard on this model
  • Reservoir level sight glass
  • Standard NPT process fittings

Options

Electrical

  • Emergency Stop Button

Alarms

  • Audible Alarm
  • Beacon Alarm

Control Instrument

MG Series Control Instrument
  • Graphic LCD display with Intuitive Navigation
  • Digital refrigerant pressure display
  • Digital water pressure display
  • Plain language error message reporting
  • Controls hot gas bypass or digital scroll compressor for Capacity Control
  • Alarm output with audible signal
  • Industry 4.0 ready with Modbus RTU or SPI communication included, Modbus TCP communication optional
  • High water temperature shut down feature

Support Documents

Literature
Literature PDF for BGD-5A
Download
Updated on September 2020
Manual
Operating Manual for BGD-5A
Download
Updated on April 7, 2022