Glycol Chiller | 1.5 Horsepower | Indoor Unit

Glycol Chiller | 1.5 Horsepower | Indoor Unit

BC-1.5A
  • Air-cooled glycol chillers are purpose built for the unique requirements of breweries and distilleries.
  • Set up for low temperature operation and high flow, the glycol chiller is designed to circulate glycol through fermentation tanks, conditioning tanks, wort chiller and storage rooms.
  • Temperature control is achieved by using a “tailor made” microprocessor control instrument designed and manufactured exclusively for this glycol chiller.
  • The electrical cabinet is NEMA 1 rated.
  • A rugged frame supports the the components in these glycol chillers.
  • Shipment is made via enclosed trailer.
  • This glycol chiller is designed for indoor installation.
Loading pricing...
Immediate Pricing
9,360Cooling Capacity BTU
1½Compressor HP
3.6Gallons/Minute (GPM)
  • Specifications
  • Features
  • Options
  • Control Instrument
  • Support Documents

Specifications

Cooling Capacity
Glycol Temperature @ 25°F: 9360 BTU/hr
Glycol Temperature @ 50°F: 16320 BTU/hr
Compressor
Horsepower: 1½
Type: Scroll
Air-Cooled Condenser
Type: Fan
CFM: 1100
Ambient: 90°F
Evaporator
Type: Immersed Coil
Refrigerant
Type: R-513A
Classification: A1 (Non-Flammable)
Low Global Warming Potential (GWP)
Process Pump
Horsepower: ½
Flow: 3.6 GPM
Reservoir Capacity
Capacity: 6 Gallons
Lid: Standard
Process Connections
To Process: ½"
From Process: ½"
Full Load Amperage
230/1/60: 20
Dimensions
Height: 38½"
Width: 24"
Depth: 29"
Weight
Shipping: 350 LBS
Specification Notes:
  1. Since product innovation and improvement is our constant goal, all features and specifications are subject to change without notice or liability. Selection of certain optional features may change listed specifications.
  2. Cooling capacity: Rated tons at 12,000 BTU/hr/ton. The minimum recommended operating temperature when no glycol is used is 48°F.
  3. Ambient conditions: Loss of capacity and/or difficulty operating may occur at higher ambient temperatures. The minimum recommended ambient temperature is 60°F.

Features

Refrigerant Circuit

  • R-513A refrigerant
  • Scroll compressor
  • Microprocessor controlled 50% hot gas by-pass capacity control system
  • Suction service valve
  • Discharge service valve
  • Air-Cooled condenser
  • Internal to Unit
  • Fan induced air flow
  • Brazed plate evaporator
  • Stainless steel plates
  • Copper brazing material
  • Refrigerant sight glass with moisture indicator
  • Filter-drier
  • Thermostatic expansion valve
  • Liquid line solenoid valve

Electrical

  • Nema 1 control cabinet
  • Branch Circuit Fusing
  • Process pump motor starter
  • Compressor contactor
  • 10′ factory installed power cord with stain relief

Coolant Circuit

  • Brass positive displacement pump
  • Internal Reservoir
  • Insulated
  • Non-ferrous polyethylene construction
  • Reservoir lid is standard on this model
  • Reservoir level sight glass
  • Standard NPT process fittings

System Limit Devices

  • High refrigerant pressure
  • Low refrigerant pressure
  • Process pump motor overload

Frame Construction

  • Stainless steel frame and enclosure panels
  • Lift-off top cover panel
  • Compact physical size
  • Stainless steel cross frame
  • Castors – for portability
  • Designed for indoor installation

Warranty

Options

Mstrong>Refrigerant Circuit

  • Air Inlet filter and protection screen
  • Hot Gas Bypass
  • Gauge Package

Electrical

  • UL508A Enclosed Electrical Panel
  • Emergency Stop Button

Coolant Circuit

  • Overhead Piping Kit
  • Process Line Shut Off Valves

Alarms

  • Audible Alarm
  • Beacon Alarm

Control Instrument

M1 Series Control Instrument
  • Continuous To Process temperature display
  • Selectable Setpoint temperature display
  • Illuminated ON/OFF power switch
  • Soft touch Setpoint selection keys
  • Illuminated Chiller On / Off switch
  • Bright and easy-to-read LED Temperature display window
  • Basic chiller diagnostics with Refrigeration Fault light
  • Machine Status with Compressor and Capacity Control indicating lights
  • Basic Machine Diagnostics with Refrigeration Fault indicating light

Support Documents

Literature
Literature PDF for BC-1.5A
Download
Updated on September 2020
Manual
Operating Manual for BC-1.5A
Download
Updated on September 4, 2020