Inline Filters | MLS Series | MLS-4

Inline Filters | MLS Series | MLS-4

MLS-4
  • Highly efficient stainless steel strainers which feature a large conical screen offering substantially more filtering screen area versus traditional y-strainers or basket strainers.
  • Water enters the bottom of the strainer housing and flows upward. Heavier debris and particulate is accelerated downward away from the conical screen into the sizable reservoir at the base of the strainer. The debris can then be flushed from the reservoi
  • The flow path through the strainer in combination with the large filtering screen surface area allows these filters to operate with less than a 1 psi pressure drop at the maximum flow rate when clean.
Loading pricing...
Immediate Pricing
4 InchesPipe Size
350 GPMMax Flow
  • Specifications
  • Features
  • Options
  • Support Documents

Specifications

Maximum Flow Rate
GPM: 350
Working Pressures
PSI: 125
Flush Port Size
NPT: 1½
Unit Dimensions
Canister Diameter: 11½"
Height: 26"
Total Width: 19"
Connections
Process: 4"
Type: Flange
Lid
Style: Clamp
Unit Dry Weight
Pounds: 65
Specification Notes:
  1. Since product innovation and improvement is our constant goal, all features and specifications are subject to change without notice or liability. Selection of certain optional features may change listed specifications.
  2. Dimensions are approximate and should be confirmed with the factory prior to construction planning.

Features

Construction

  • Body and filter are made of 304 stainless steel
  • 50 mesh (297 micron) and 100 mesh (149 micron) standard filter screens
  • 1/4″ NPT pressure gauge ports
  • 1/4″ air relief port

Warranty

Options

Alarms

  • Pressure differential alarm (PDA) Continuously monitors the inlet and outlet system pressure and triggers an audible and visual alarm when the pressure differential exceeds the preset limit indicating filter cleaning is required

Automated Flush

  • The Automatic Timer Flush (ATF) can be programmed to open and close the flush valve automatically, removing any debris from the filter reservoir (Not recommended when using glycol or similar addititves)

Bypass

  • Optional factory installed full size bypass to allow full system flow while isolating the filter for cleaning (pictured below)

Mesh Screens

  • A wide range of filtration levels can be maintained by selecting one of the numerous screen mesh options available including as fine as 200 mesh (74 micron)

Support Documents

Literature
Literature PDF for MLS-4
Download
Updated on September 2020
Manual
Operating Manual for MLS-4
Download
Updated on June 6, 2022