Evaporative Cooling | Energy Efficient | Non Ferrous

Evaporative Cooling | Energy Efficient | Non Ferrous

PT-210G3
  • Cooling towers are simple to operate and utilize energy efficient evaporative cooling.
  • Cooling Towers are typically used to supply cooling temperatures between
    5°F to 10°F above the ambient wet bulb conditions.
  • Warm water returning from the process is evenly distributed over the wet desk. Counter airflow driven by the fan causes a portion of the warm process water to evaporate cooling the remaining water.
  • Offering cooling towers in capacities from 45 to 270 tons in single and expanded cell systems.
Loading pricing...
Immediate Pricing
210 TonsCapacity
630 Gallons/minProcess Flow
  • Specifications
  • Features
  • Options
  • Support Documents

Specifications

Capacity
Capacity: 210 Tons
Flow Rate: 630 GPM
Direct Drive Fan
Quantity: 2
RPM: 1170
CFM: 50930
Motor
Quantity: 2
HP: 10
Total HP: 20
Full Load Amperage
230/3/60: 57.6
460/3/60: 28.8
575/3/60: 24
Connection Sizes
To Tower: 2@4"
From Tower: 2@6"
From Tower Location: bottom
Dimensions
Height: 140"
Width: 210"
Depth: 80"
Weight
Shipping: 2,250 LBS
Operating: 5,640 LBS
Shipping: 2,250 LBS
Specification Notes:
  1. Since product innovation and improvement is our constant goal, all features and specifications are subject to change without notice or liability. Selection of certain optional features may change listed specifications.
  2. Cooling capacity: Tons based on cooling water from 95°F to 85°F at 3 gpm per ton and 78°F wet-bulb temperature. Connection sizes shown are when the tower is used with remote sump. Consult factory for connection size when the base of the tower will be used as the reservoir.
  3. Dimensions are approximate and should be confirmed with the factory prior to construction planning.

Features

Tower Cell Design

  • Two cell design
  • Total non-ferrous construction materials
  • Counter-flow air movement
  • Structural galvanized steel base

Fan

  • Air foil shaped blades for increased air flow
  • Blades are made of a glass fiber reinforced polymer
  • Blades are factory set at best angle for maximum air
  • Direct drive mechanics

Water Distribution Header

  • Non-ferrous PVC ‘cross’ construction
  • Stationary
  • Computer designed spray pattern
  • Large orifice spray heads
  • PVC spray heads
  • Drift eliminator prevents over spray and water loss

Inlet Louvers

  • PVC construction
  • Easily removed for cleaning
  • Vertical orientation to eliminate water loss
  • Directs air flow for even distribution through wet deck
  • Helps prevent air-born debris from entering cell

Shell Construction

  • High strength fiberglass molding
  • 1/2″ of structural thickness in reinforced areas
  • UV stabilized coating
  • Acrylic adhesive bonding between shell halves
  • Polyurethane sealant

Motor

  • TEFC construction
  • Mounted on a galvanized steel frame
  • Supported on reinforced fiberglass shell area
  • Mounted to shell with stainless steel fasteners

Inspection Covers

  • Easily removed
  • Seamless gasket sealing
  • Allows for inspection on cell interior and replacement of wet deck

Media Fill

  • Stacked honeycomb pattern maximizes water and air flows for greater cooling efficiency
  • PVC construction

Warranty

  • 10 Year on the fiberglass shell
  • 5 Year on the motor/fan assembly

Options

Cooling Tower Design

  • Basin Float Valve
  • Mechanical float and valve
  • 1/2″ supply connection
  • Factory or field installed
  • Side Outlet
  • PVC flange
  • Factory installed
  • Fan Starter Kit
  • Motor start contactor
  • Motor overload relay
  • Nema 1 enclosure
  • Fan thermostat

Cooling Tower Stands

  • 5′ Galvanized Tower Stand
  • 10′ Galvanized Tower Stand
  • 15′ Galvanized Tower Stand

Support Documents

Literature
Literature PDF for PT-210G3
Download
Updated on January 19, 2018
Manual
Operating Manual for PT-210G3
Download
Updated on June 30, 2024