Regal Process Pumps
- FYI #148
Use this chart to determine the Efficient Use Zone for Regal Series process pumps. If you have any questions, please contact the Advantage Sales Department at 317-887-0729.
How To Use This Table: Find the desired GPM in the left axis, read to the right to find desired pressure in BOLD RED and then read up to select the pump horsepower.
KEY:
- Lite Face = Inefficient Use Zone (Above the Efficient Use Zone)
- Bold Face = Efficient Use Zone
- Lite Face is Overload Zone (below the Efficient Use Zone)
Flow (GPM)
Horsepower (HP)
1.0
1.5
2.0
3.0
5.0
7.5
5
10
15
38
20
37
38
25
36
37
30
34
36
42
62
35
31
35
38
41
61
40
29
33
36
40
60
45
26
32
34
39
59
79
50
23
30
32
38
58
78
55
20
28
29
37
57
76
60
18
25
27
36
56
75
65
15
23
25
35
55
74
70
20
24
34
54
73
75
22
33
53
72
100
20
28
48
68
125
19
22
44
63
150
18
39
58
175
12
34
53
200
7
30
48
225
24
43
250
19
38
275
15
33
300
10
29
325
24
350
19
375
14
400
- Notes:
- All motors are overload protected, of ODP construction, and 230/480/3/60 power requirements.
- TEFC motors and 208.380.575 voltages are available.
- All pumps are end-suction centrifugals.
For more information about process pump for Regal Series hot oil temperature control units call the Advantage Sales Department at 317-887-0729.
Download the PDF document

Download PDF