Water temperature control units circulate temperature stabilized water through the process for process temperature control.
The temperature control range of this unit is 32°F - 250°F.
A pump circulates water through the process. A heater and a cooling valve work together to control the water temperature.
This temperature control unit requires a plant water supply source.
Advantage temperature control units are portable, built on casters to easily move the unit between processes.
Units are available with a variety of different control instruments, heater sizes, cooling valves and physical packages.
SPECIFICATIONS
SK-1635-LE
Heater (2)
kW : 16
Process Pump
HP : 3/4
GPM : 35
PSI : 30
Cooling Valve
Type : Modulating
Size : 1/2"
Control Instrument
Control : LE Series
Maximum Temperature : 250°F
(6) Minimum Temperature : 32°F
Construction
• Nema 1 control cabinet with branch circuit protection
• ABS facia with stainless steel enclosure panels
Full Load Amperage (3)
230/3/60 : 42.2
460/3/60 : 21.1
575/3/60 : 17.6
Connection Sizes
To Process : 1-1/4"
From Process : 1-1/4"
Water Supply : 1/2"
Drain : 1/2"
Dimensions
Height : 28-1/4"
Width : 12-1/2"
Depth : 19-1/2"
Weight (5)
Shipping : 205 lbs
Warranty
• 2 years covering heater & cooling valve
• 4 years covering LE Series control instrument
• Lifetime covering pump seal (parts only)
• 2 years covering balance of machine
Specification Notes:
1. Since product innovation and improvement is our constant goal, all features and specifications are subject to change without notice or liability. Selection of certain optional features may change listed specifications.
2. Derate heater output by 25% for 208/3/60 operation.
3. Full load amps are higher than run load amps and must be used for sizing disconnects and supply wiring. Not for construction. Consult factory for power requirements of unit as configured and on selected options.
4. Consult factory for 50HZ operation.
5. Unit weight crated for shipment.
6. The Sentra cannot achieve temperatures below the cooling water supply temperature and will provide warmer water to process compared to the cooling water temperature even with the cooling valve fully open. Consult Factory for more information.
FEATURES
Process Pump:
3/4 HP process pump
Stainless steel shaft
Horizontal motor extends bearing and seal life
ODP (open drip proof) motor
Pump seal flush line
Custom designed impeller and casing
High grade mechanical contactor with over current, phase loss and short circuit protection
Cooling Vavle:
1/2" AVT™ modulating valve
0% to 100% aperature range
Microprocessor controlled
Integral to cooling cylinder
Field Serviceable
Heater:
16 kW
Stainless steel sheath
Built-In flange for bolt-in mounting
Mechanical contactor
Control Instrument:
'LE' Series Control Instrument
Controls temperature from 30°F t0 250°F
Cabinetry & Frame:
Stainless steel panels
Hinged electrical cabinet door
Lift-off mechanical cover
Thermoformed polymer front panel
Portable, on castors
Limits:
Water supply pressure switch
Process pump motor overload protection
Process pressure relief valve
High temperature limit protection
Control circuit fuse
Electrical:
DIN rail mounted electrical components
UL approved components
Nema 1 electrical construction
Pressure Gauges:
To process
From process
Heating & Cooling Cylinders:
Twin cylinders - separate heating and suction tanks
Made from cast iron by custom molds
Reinforced bosses for process and ancillary connections
NPT process connections
Each cylinder is flanged mounted to the pump casing
Warranty (standard units):
Lifetime on the pump seal
4 Years on the control instrument
2 Years on the cooling valve
2 Years on the mechanical system
OPTIONS
Control Instrument
SPI communications cable - 20'
'VE' Series Control Instrument Changes Model to SK-1635-VE
Dual Zone Dolly with Water Manifold
System Alarms
Visual / audible beacon
High dB Audible Alarm
Unit
Stacking Stand with water manifold and/or single electrical connection
Dual Zone dolly with water manifold and/or single electrical connection
Mold Purge
Closed Circuit Cooling With Expansion Tank
Closed Circuit Cooling
Total Non-Ferrous Unit
Cabinetry
Rear Panel Cover
Electrical
Power Disconnect Switch
Solid State Heater Contactor
Other Pumps
7-1/2 HP @ 100 GPM Changes Model to SK-16100-LE
5 HP @ 90 GPM Changes Model to SK-1690-LE
3 HP @ 80 GPM Changes Model to SK-1680-LE
2 HP @ 75 GPM Changes Model to SK-1675-LE
1-1/2 HP @ 65 GPM Changes Model to SK-1665-LE
1 HP @ 45 GPM Changes Model to SK-1645-LE
Other Heaters
34 kW Changes Model to SK-3435-LE
24 kW Changes Model to SK-2435-LE
10 kW Changes Model to SK-1035-LE
CONTROL INSTRUMENT
Sentra LE Series
LE Series Control Instrument
Control temperature from 32°F - 250 °F
Continuous To Process temperatur display
Continuous Setpoint temperature display
Temperature display in Fahrenheit or Celsius
Digital Setpoint selection
Status indicators for Power On, Pump On, Heat On and Cool On
Image is typical. Actual unit appearance will vary according to specifications and options.
-
Need Application Assistance?
Our Experienced Team Can Save You Time & Money.
Tell Us About Your Project
Close
This site uses cookies to offer you a better browsing experience. Learn more about how Advantage Engineering, Inc. uses cookies by contacting the site
administrator at admin@advantageengineering.com By closing this banner, scrolling this page, clicking a link or continuing to browse otherwise, you agree to the use of cookies.
Please refer to the Advantage Engineering Privacy Policy.