To see IMMEDIATE online pricing, please complete the form below for the M1-4A
Pricing will be displayed on our website when you fill out the form below and click Get Pricing Now.
Get Pricing Now
Your privacy is assured, of course. Your information will be used by Advantage and its representatives only. It will not be provided or sold to others. It will be used for purposes of this inquiry only.
Portable chillers use mechanical refrigeration to cool recirculated fluids that support industrial process cooling applications.
Portable chillers include an internal pumping system and reservoir system.
Portable chillers can be moved between use points as needed.
Air-Cooled chillers use indoor ambient air to dissipate the heat from the refrigeration system.
SPECIFICATIONS
M1-4A
Unit Cooling Capacity
(2) Tons : 4
kW : 14.0
Compressor
HP : 4
Type : Scroll
Process Pump
HP : 3/4
GPM : 9.6
PSI : 30
Type : Centrifugal
Construction : Stainless Steel
Air-Cooled Condenser
Type : Fan
Fan Quantity :
Fan Horsepower : (for each motor)
CFM : 5,000
(3) Ambient : 95°F
Refrigerant
Type : R-410A
Full Load Amperage
230/3/60 : 24
460/3/60 : 12
575/3/60 : 10
Reservoir Capacity
Holding : 25 gal
Lid : Standard
Auto Make-Up : Optional
Dimensions
Height : 60"
Width : 34"
Depth : 40"
Process Connections
To Process : 1-1/4"
From Process : 1-1/4"
Weight
Shipping : 800 lbs
Specification Notes:
1. Since product innovation and improvement is our constant goal, all features and specifications are subject to change without notice or liability. Selection of certain optional features may change listed specifications.
2. Tons capacity at 12,000 BTU/ton per hour @ 50°F LWT @ " 115°F condensing temperature. Capacities may be +/- 5% as reserved by the compressor manufacturer. Operating at temperatures below 50° will reduce chiller capacity. The minimum recommended operating temperature when no glycol is used is 48°F.
3. Design ambient conditions. Loss of capacity and/or difficulty operating will occur at higher ambients. Minimum recommended ambient is 60°F.
4. Full load amps are higher than run load amps and must be used for sizing disconnects and supply wiring.
5. Approximate unit weight crated for shipment.
FEATURES
Refrigerant Circuit:
R410A refrigerant - Non-Ozone depleting - Low global warming impact
Image is typical. Actual unit appearance will vary according to specifications and options.
-
Need Application Assistance?
Our Experienced Team Can Save You Time & Money.
Tell Us About Your Project
Close
This site uses cookies to offer you a better browsing experience. Learn more about how Advantage Engineering, Inc. uses cookies by contacting the site
administrator at admin@advantageengineering.com By closing this banner, scrolling this page, clicking a link or continuing to browse otherwise, you agree to the use of cookies.
Please refer to the Advantage Engineering Privacy Policy.