Comparison of Maximum HE & LE Series Instruments

Maximum HE Control Instrument
Maximum HE Control Instrument

Maximum LE Control Instrument
Maximum LE Control Instrument

  • +-Operators
  • Soft Touch Operators
  • MKHE: Yes
  • MKLE: Yes
  • Up / Down Arrows (Digital Setpoint)
  • MKHE: Yes
  • MKLE: Yes
  • Display Select
  • MKHE: Yes
  • MKLE: Yes
  • Off / On Rocker Switch
  • MKHE: No
  • MKLE: No
  • Power On Button
  • MKHE: Yes
  • MKLE: Yes
  • Power Off Button
  • MKHE: Yes
  • MKLE: Yes
  • +-Temperature Display
  • Continual To Process Temperature Display
  • MKHE: Yes
  • MKLE: Yes
  • Continual Setpoint Temperature Display
  • MKHE: Yes
  • MKLE: Yes
  • Selectable From Process Temperature Display
  • MKHE: Yes
  • MKLE: Yes
  • °F or °C Temperature Display
  • MKHE: Yes
  • MKLE: Yes
  • % of Capacity Display
  • MKHE: Yes
  • MKLE: No
  • +-Control Output Display
  • Compressor On
  • MKHE: Yes
  • MKLE: Yes
  • Coolant Pump On
  • MKHE: Yes
  • MKLE: Yes
  • Power On
  • MKHE: Yes
  • MKLE: Yes
  • +-Flow Display
  • Digital Flow Meter
  • MKHE: Yes
  • MKLE: No
  • GPM or LPM Flow Display
  • MKHE: Yes
  • MKLE: No
  • Flow Deviation Alarm
  • MKHE: Yes
  • MKLE: No
  • +-Diagnostic Display
  • 3 Ø Fault
  • MKHE: Yes
  • MKLE: No
  • Pump Overload Tripped
  • MKHE: Yes
  • MKLE: Gro
  • Low Flow
  • MKHE: Yes
  • MKLE: Yes
  • High Pressure
  • MKHE: Yes
  • MKLE: Group*
  • Low Pressure
  • MKHE: Yes
  • MKLE: Group*
  • Temperature Deviation
  • MKHE: Yes
  • MKLE: E Code
  • Freezestat
  • MKHE: Yes
  • MKLE: Yes
  • Communications Activity
  • MKHE: Yes
  • MKLE: No
  • % Capacity Display
  • MKHE: Yes
  • MKLE: No
  • Reservoir Level Fault
  • MKHE: Yes
  • MKLE: Yes
  • +-Communications
  • SPI Protocol
  • MKHE: Yes
  • MKLE: Yes
  • CAMAC Protocol
  • MKHE: Yes
  • MKLE: No
  • Custom Protocol
  • MKHE: Optional
  • MKLE: No
  • 2 Wire Interface
  • MKHE: Yes
  • MKLE: Yes
  • 4 Wire Interface
  • MKHE: Yes
  • MKLE: Yes
  • +-Advanced Features
  • Remoteable Display
  • MKHE: Optional
  • MKLE: No
  • 5° or 10° Deviation Band
  • MKHE: No
  • MKLE: Yes
  • Adjustable Deviation Band
  • MKHE: Yes
  • MKLE: No
  • +-Other
  • 4 Year Warranty
  • MKHE: Yes
  • MKLE: Yes
  • Number of Sensors
  • MKHE: 2
  • MKLE: 2

For more information about Maximum Series Instruments for Portable Water Chillers call the Advantage Sales Department at 317-887-0729.

  • Download This Article
  • Download FYI 255
  • Download Now
  • 1 Page document
    in full color.
  • Acrobat PDF
    Size: 1.0 MB.

Need Application Assistance?

Our Experienced Team Can Save You Time & Money.

Tell Us About Your Project

Close