Advantage WPT Series water-cooled central chilling modules use mechanical refrigeration to cool recirculated fluids that support industrial process cooling applications.
20°F to 70°F process fluid temperatures.
WPT Series chillers combine one or more refrigeration circuits to chill fluid. A separate reservoir and pumping system is required to circulate chilled fluid to the use points.
Water-cooled chillers require a secondary water source (typically cooling tower water) to dissipate the heat from the refrigeration system.
PRICING
SPECIFICATIONS
C-10WPT
Refrigerant Zones
Quantity: : 1
Compressor
Quantity : 1
HP : 10
Type : Scroll
(2) Total Capacity : 10
Refrigerant
Type : R-410A
Water-Cooled Condenser
(3) City Water : 15 GPM
(4) Tower Water : 30 GPM
Connection Sizes
To Process : 1-1/4"
From Process : 1-1/4"
Full Load Amperage (5)
230/3/60 : 44
460/3/60 : 22
575/3/60 : 18
Dimensions (7)
Height : 52"
Width : 24"
Depth : 62"
Weight (8)
Shipping : 545 lbs
Specification Notes:
1. Since product innovation and improvement is our constant goal, all features and specifications are subject to change without notice or liability. Selection of certain optional features may change listed specifications.
2. Tons capacity at 12,000 BTU/ton per hour @ 50°F LWT @ 105°F condensing temperature. Capacities may be +/5% as reserved by the compressor manufacturer. Capacity multipliers are 50°F - 1.00 ; 40°F - .80 ; 30°F - .60 ; 20°F - .40. The minimum recommended operating temperature when no glycol is used is 48°F.
3. Flow rate (GPM) is based on 60°F city water source with a clean condenser.
4. Flow rate (GPM) is based on 85°F tower water source with a clean condenser.
5. Full load amps are higher than run load amps and must be used for sizing disconnects and supply wiring. Not for construction. Consult factory for power requirements of unit as configured and on selected options.
6. Consult factory for 50HZ operation.
7. Approximate dimensions. Not for construction purposes.
Image is typical. Actual unit appearance will vary according to specifications and options.
Need Application Assistance?
Our Experienced Team Can Save You Time & Money.
Tell Us About Your Project
Close
This site uses cookies to offer you a better browsing experience. Learn more about how Advantage Engineering, Inc. uses cookies by contacting the site
administrator at admin@advantageengineering.com By closing this banner, scrolling this page, clicking a link or continuing to browse otherwise, you agree to the use of cookies.
Please refer to the Advantage Engineering Privacy Policy.