Advantage Titan air-cooled central chillers use mechanical refrigeration to cool recirculated fluid that support industrial process cooling applications.
20°F to 70°F process fluid temperature range.
Titan systems combine one or more refrigeration circuits with a large capacity reservoir and pumping system assembled on a single skid for low ease of installation.
Air-cooled chillers use ambient air to dissipate the heat from the refrigeration system.
The refrigeration system, controls, reservoir and pumping system remain inside while the remote air-cooled condenser is located outside.
PRICING
SPECIFICATIONS
TI-180A
Refrigerant Zones
Quantity : 3
Compressor
Quantity : 6
HP : 30
Type : Scroll
(2) Total Capacity : 180 Tons
Refrigerant
Type : R-410A
Process Pump
HP : 25
GPM : 540
PSI : 55
Evaporator Pump (3)
HP : 15
GPM : 390
Reservoir Capacity
Operating : 1,00 gal
Holding : 1,75 gal
Connection Sizes
To Process : 6"
From Process : 6"
Water Make-Up : 1-1/2"
Overflow : 4"
Full Load Amperage (5)
230/3/60 : 884
460/3/60 : 442
575/3/60 : 354
Dimensions
Height : 114"
Width : 147"
Depth : 147"
Weight
(7) Shipping : 10,500 lbs
Operating : 23,700 lbs
Specification Notes:
1. Since product innovation and improvement is our constant goal, all features and specifications are subject to change without notice or liability. Selection of certain optional features may change listed specifications.
2. Tons capacity at 12,000 BTU/ton per hour @ 50°F LWT @ 115°F condensing temperature. Capacities may be +/5% as reserved by the compressor manufacturer. Capacity multipliers are 50°F - 1.00 ; 40°F - .80 ; 30°F - .60 ; 20°F - .40.
3. Consult pump curve for exact pump performance.
4. Selection of optional pumps for higher flow rates will raise the minimum recommended operating temperature when no glycol is used.
5. Full load amps are higher than run load amps and must be used for sizing disconnects and supply wiring. Not for construction. Consult factory for power requirements of unit as configured and on selected options.
6. Consult factory for 50HZ operation.
7. Unit weight crated for shipment. Air-cooled units shipped in two units. Basic field assembly required for Air-cooled units.
Remote Air-Cooled Condenser
Capacity (1)
R410A @ 1° TD : 46.43 MBTU/hr
R410A @ 20° TD : 61.91 tons
Fans (2)
Quantity : 5
RPM : 1140
Connections (3)
Gas : 2-5/8"
Liquid : 2-1/8"
Full Load Amperage
460/3/60 : 14.7
Construction
Tube Material : Copper
Fin Material : Aluminum
Coating : None
Fins Per Inch : 19
Dimensions
Height : 54"
Width : 44-5/8"
Depth : 277-1/2"
Weight (4)
Weight : 1950 lbs
Circuits Served
Maximum : 1
Reference : KCL-95-KR
Specification Notes:
1. Since product innovation and improvement is our constant goal, all features and specifications are subject to change without notice or liability. Selection of certain optional features may change listed specifications.
2. Tons capacity at 12,000 BTU/ton per hour @ 50°F LWT @ 115°F condensing temperature. Capacities may be +/5% as reserved by the compressor manufacturer. Capacity multipliers are 50°F - 1.00 ; 40°F - .80 ; 30°F - .60 ; 20°F - .40.
3. Consult pump curve for exact pump performance.
4. Selection of optional pumps for higher flow rates will raise the minimum recommended operating temperature when no glycol is used.
5. Full load amps are higher than run load amps and must be used for sizing disconnects and supply wiring. Not for construction. Consult factory for power requirements of unit as configured and on selected options.
6. Consult factory for 50HZ operation.
7. Unit weight crated for shipment. Air-cooled units shipped in two units. Basic field assembly required for Air-cooled units.
FEATURES
Refrigerant Circuit:
Scroll compressors
Compressor suction service valve
Compressor discharge service valve
Brazed Plate evaporator
Remote air-cooled condenser:
Heavy gauges galvanized steel cabinet on heavy duty legs
Enhanced copper tubing with aluminum fins
Energy efficient motors
Direct drive fans with quiet "swept wing" blades
Non-fused power disconnect
(Condenser shipped separately. Requires field installation.)
Liquid line solenoid valve
Refrigerant sight glass with moisture indicator
Thermostatic expansion valve
Capacity control via hot gas bypass
Non-Ozone depleting refrigerant
Refrigerant Limit Devices:
Refrigerant high pressure
Refrigerant low pressure
Evaporator flow
Electrical:
Nema rated electrical cabinet
Fused transformer
Fused power motor starters
Fused compressor starters
Power entry terminal block
Coolant Circuit:
Large capacity process pump with Suction and Discharge service valves
Evaporator pump with Suction and Discharge service valves
Coolant Circuit Limit Devices:
Pump motor overload relay
Coolant freezestat
Reservoir:
Seemless rotationally molded and non-rusting polyethylene
Full 3/8" dense foam insulation
Drain valve
Overflow port
Automatic water level control
Hot / cold section baffle
Structural steel base
Pump decking
Spare pump port
Pressure Gauges:
Refrigerant high pressure
Refrigerant low pressure
Coolant pressure
Warranty:
1 Year covering parts and labor
2nd Year complementary preventive maintenance visit (U.S. only)
Image is typical. Actual unit appearance will vary according to specifications and options.
Need Application Assistance?
Our Experienced Team Can Save You Time & Money.
Tell Us About Your Project
Close
This site uses cookies to offer you a better browsing experience. Learn more about how Advantage Engineering, Inc. uses cookies by contacting the site
administrator at admin@advantageengineering.com By closing this banner, scrolling this page, clicking a link or continuing to browse otherwise, you agree to the use of cookies.
Please refer to the Advantage Engineering Privacy Policy.