Advantage BC & BCD Series air-cooled chillers use mechanical refrigeration to cool recirculated fluid that support industrial process cooling applications.
Glycol chillers are configured to produce fluid temperatures between 25°-30°F using a mixture of water & glycol to prevent the fluid from freezing but can also be adjusted to produce fluid temperatures as low as 20°F and as high as 70°F.
Air-cooled chillers use ambient air to dissipate the heat from the refrigeration system.
BC-N4 & BCD-N4 models are designed for outdoor installation.
PRICING
SPECIFICATIONS
BGD-7.5A-N4
Refrigerant Zones
Quantity : 1
Capacity
(2) BTH @ 25°F : 45,512
(3) BTH @ 50°F : 86,400
Compressor
HP : 7.5
Type : Digital Scroll
Refrigerant
Type : HFC-410A
Air-Cooled Condenser
# of Fans : 2
Evaporator
Type : Brazed Plate
Process Pump
(4) HP : 2
(5) GPM : 18
PSI : 50
Reservoir Capacity
Capacity : 65 gal
Construction : Polyethylene
Process Connection
Size & Type : 1-1/4" NPT
Dimensions (6)
Height : 61"
Width : 68"
Length : 46"
Controller
Instrument Type : M1 with Remote & 50' Cable
System Amperage (7)
460/3/60 : 26
230/3/60 : 51
230/1/60 : 94
Specification Notes:
1. Since product innovation and improvement is our constant goal, all features and specifications are subject to change without notice or liability. Selection of certain optional features may change listed specifications.
2. Capacity at 25°F LFT and 115 °F condensing temperature. Capacities may be +/5% as reserved by the compressor manufacturer. The minimum recommended operating temperature when no glycol is used is 48°F.
3. Capacity at 50°F LFT and 115 °F condensing temperature. Capacities may be +/5% as reserved by the compressor manufacturer. The minimum recommended operating temperature when no glycol is used is 48°F.
4. Consult pump curve for exact pump performance.
5. Selection of optional pumps for higher flow rates will raise the minimum recommended operating temperature when no glycol is used.
6. Approximate dimensions. Not for construction purposes.
7. Full load amps are higher than run load amps and must be used for sizing disconnects and supply wiring. Not for construction. Consult factory for power requirements of unit as configured and on selected options.
Image is typical. Actual unit appearance will vary according to specifications and options.
-
Need Application Assistance?
Our Experienced Team Can Save You Time & Money.
Tell Us About Your Project
Close
This site uses cookies to offer you a better browsing experience. Learn more about how Advantage Engineering, Inc. uses cookies by contacting the site
administrator at admin@advantageengineering.com By closing this banner, scrolling this page, clicking a link or continuing to browse otherwise, you agree to the use of cookies.
Please refer to the Advantage Engineering Privacy Policy.