INDUSTRIAL COOLING TOWER CELLS
Standard Features and Options : 20 - 200 Tons

MT Series Cooling Tower Cells MT Series cooling towers offer total a sturdy galvanized base, frame and enclosure panels with PVC wet deck and drift eliminator. An axial flow fan generates the cross air-flow.

WET DECK SURFACE... an efficient polyvinyl chloride (PVC) wet deck surface designed is furnished as standard in all metal Cooling Towers. The wet deck surface is impervious to rot, decay, and biological attack. The special configuration with integral eliminators provides maximum air/water contact and low air pressure drop to ensure efficient heat transfer while minimizing power requirements.

AXIAL FLOW FANS... fixed pitch heavy-duty axial flow fans are used on all metal Cooling Towers to assure consistent performance. The fans are matched to the specific cooling tower size for maximum efficiency.

HEAVY DUTY CONSTRUCTION... the casing and basins are constructed of G210 hot-dip galvanized steel, with exposed edges given a protective coat of zinc-rich compound. The exterior of the cooling tower shall be finished with Zinc Chromatized Aluminum paint after assembly. This heavy-duty construction provides the protection, strength and rigidity required for lasting, trouble free operation. All principal panels are formed with double-brake flanges for maximum strength and die-punched to assure accurate mating with adjacent panels.

DRIVES... metal Cooling Towers are either direct drive (standard on models 6 to 20) or V-belt drive. Where V-belt drives are used, they are designed for not less than 150% of motor nameplate horsepower. The belts are easily adjusted by means of a threaded bolt and nut arrangement.

FAN SHAFT AND BEARINGS... metal models 6 to 20 tons have direct driven fans mounted directly on the motor shaft with no additional fan shaft bearings or couplings. Metal models 26 to 536 tons use solid steel fan shafts supported by heavy-duty, grease packed, self aligning bearings with cast iron, pillow-block type housing. Bearings are furnished with extended lube lines to permit easy relubrication.

MOTOR... Drip-proof motors with 1.15 service factor are furnished as standard. In addition to being suitable for outdoor service, the motors are mounted on an adjustable base located near the base of the unit in the dry entering air stream for greater reliability and easy servicing.

AIR INLET CYLINDER... air inlet cylinders are designed to streamline air entry and minimize fan tip losses for maximum efficiency.

PROTECTION FOR MOVING PARTS...all moving parts are protected by inlet screens on the front of the fan housing or by belt guards around the sheaves and belts. Screens or belt guards are easily removable for access to fans, bearings, motor and drives.

WATER DISTRIBUTION SYSTEM... the open gravity feed hot water basin with built in velocity breaker assures even water distribution through the large diameter metering orifices.

ACCESS... leakproof, circular access doors are furnished to provide convenient access to the interior for inspection and adjustment of the float valve, cleaning the lift out strainers, and flushing the sump.

STRAINER... a strainer assembly of anti-vortexing design is standard on all units. Large area lift-out strainer screens are provided to avoid the need for frequent servicing while the perforated strainer surface washes clean quickly when service is required. The anti-vortexing baffle is specially designed to prevent air entrainment.

LIFTING DEVICES... lifting devices are located at the top of all metal Cooling Towers near each corner for rigging convenience.

ENGINEERING SERVICES... for every water system purchase, ADVANTAGE supplies complete piping drawings for contractor bidding and installation services. ADVANTAGE staffs an experienced engineering department to assist in the piping design. Contact your Advantage Sales Rep or the Factory for more information on custom engineering services.

CHECKMATE™ CONTROL SYSTEM FOR COOLING TOWER SYSTEMS

New Checkmate control system for Cooling Tower System Cooling tower systems that use Advantage Pump Tank Stations now offer the NEW Checkmate™ control system with Top Operators™ for tower or chiller pump control and tower fan control. Offered as an optional upgrade from the standard pump controls and temperature and pressure monitoring, the Checkmate™ displays offers 13 screens of system temperature, reservoir level, and alarm information. LEARN MORE

Advantage Products

MORE INFORMATION
for MT Series
Cooling Towers

Pricing & Specifications

General Product Information


Supporting Documents
Literature Literature
PDFPDF
2 Pages
Color
91 KB
Knowledge Base
PDF HTMLPDF & HTML
Documents covering the selection, service & operation of industrial cooling towers.