Click Here For An Animated Schematic
STANDARD FEATURES (1)
FRAME CONSTRUCTION:
• Stainless steel sheet metal
• Lift-off top
• Compact physical size
• Castors - for portability
REFRIGERANT CIRCUIT:
• Hermetic compressor
• Air-cooled condenser with finned tubes
• Propeller fan(s) induced air flow
• Refrigerant sight glass with moisture
indicator
• Filter-drier
• Liquid line solenoid valve
• Thermostatic expansion valve
• Coaxial evaporator
COOLANT CIRCUIT:
• Positive displacement pump
• Large capacity insulated non-ferrous
reservoir (tank lid is standard on this model)
• Reservoir level sight glass
• Standard NPT process fittings
• Low flow bypass valve
ELECTRICAL:
• Process pump motor starter
• Compressor motor contactor
• Fused transformer
• Power entry terminal block
• Factory installed 10' power cord
SYSTEM LIMIT DEVICES:
• High pressure limit
• Low pressure limit
• Internal compressor overload
• Control circuit fuse
WARRANTY:
• 1 year covering parts and labor
Warranty Statement
INSTRUMENT
M1 Series (standard instrument)
• Continuous To Process temperature
display
• Selectable Setpoint temperature
display
• Illuminated ON/OFF power switch
• Soft touch Setpoint selection keys
• Bright and easy-to-read LED
Temperature display window
• Machine Status with Compressor
and Capacity Control indicating
lights
• Basic Machine Diagnostics with
Refrigeration Fault indicating
light
OPTIONS
REFRIGERANT CIRCUIT:
• Compressor CPR valve (for setpoints above 65°F)
COOLANT CIRCUIT:
• Overhead piping kit : factory or field installed
• No reservoir tank for gravity return applications
• Low flow bypass valve : manual or automatic
• Process line shut-off valves
• Larger process pumps
WARRANTIES:
• Extended compressor warranty
SPECIFICATIONS (1)
Model: M1-.75A![]()
Specification Notes:
1. Since product innovation and improvement is our constant goal, all features and specifications are subject to change without notice or liabililty.
Selection of certain optional features may change listed specifications.
2. Tons capacity at 12,000 BTU/ton per hour @ 50°F LWT @ 115°F condensing temperature. Capacities may be +/- 5% as reserved by the compressor
manufacturer. Capacity multipliers are 50°F - 1.00 ; 40°F - .80 ; 30°F - .60 ; 20°F - .40. The minimum recommended
operating temperature when no glycol is used is 48°F.
3. Design ambient conditions. Loss of capacity and/or difficulty operating will occur at higher ambients. Minimum recommended ambient is 60°F.
4. Full load amps are higher than run load amps and must be used for sizing disconnects and supply wiring.
5. Approximate unit weight crated for shipment.
6. See Warranty Statement #W-700 for details.