APT-RC Series process water chillers are built onto an open frame for easy access to all serviceable parts.
REFRIGERANT CIRCUIT (per zone):
• Scroll compressor
• Compressor suction service valve
• Compressor discharge service valve
• Brazed plate evaporator
• Remote air-cooled condenser
• Liquid receiver
• Oil separator
• Liquid line solenoid valve
• Refrigerant sight glass with
moisture indicator
• Thermostatic expansion valve
• Capacity control via hot gas bypass
• Non-Ozone depleting refrigerant
LIMIT DEVICES (per zone):
• Refrigerant high pressure
• Refrigerant low pressure
• Evaporator flow
• Instrument circuit fuse
PRESSURE GAUGES (per zone):
• Refrigerant high Pressure
• Refrigerant low Pressure
• Coolant pressure
WARRANTY (US & Canada)
• 1 year parts and labor
Warranty Statement
ELECTRICAL
• Fused transformer
• Nema rated electrical cabinet
• Power entry terminal block
• Fused compressor motor starter on
dual and triple zone units
OPTIONS
FRAME
• Special Paint
REFRIGERANT CIRCUIT
• Compressor CCPR valve
• Compressor hour meter
COOLANT CIRCUIT
• Larger process pumps
• Standby pump and manifold
CHILLER CONTROL INSTRUMENT
• Remote display kit
• PLC with touch screen display
WARRANTIES
• Extended compressor warranty
ELECTRICAL
• UL listed electrical panel
• Disconnect
CHILLER CONTROL INSTRUMENT
Dual Zone Units

Learn More about this instrument.
• Microprocessor based multizone
controller
• Intelligent zone boards
• Compressors are staged individually
• Continuous To Process temperature
display
• Continuous Setpoint temperature
display
• Selectable from process
temperature display
• Large temperature display windows
• °F or °C temperature display
• Refrigerant circuit indicators for
Probe, Low Flow, High Pressure,
Low Pressure, Compressor,
Freezestat, Capacity Control
• Water circuit indicators for
Temperature Deviations,
Low Pressure, Probe,
Phase
• Selectable lead - lag mode
• Soft Key Operators
• SPI communications
• Audible and visual alarm
SPECIFICATIONS
Model: CCC-90APT-RC![]()
Specification Notes:
1. Tons capacity at 12,000 BTU/ton per hour @ 50°F LWT @ 115°F condensing temperature. Capacities may be +/5% as reserved by
the compressor manufacturer. Capacity multipliers are 50°F - 1.00 ; 40°F - .80 ; 30°F - .60 ; 20°F - .40.
The minimum recommended operating temperature when no glycol is used is 48°F.
2. Consult pump curve for exact pump performance.
3. Selection of optional pumps for higher flow rates will raise the minimum recommended operating temperature when no glycol is used.
4. Full load amps are higher than run load amps and must be used for sizing disconnects and supply wiring. Not for construction. Consult factory for power requirements of unit as configured and on selected options.
5. Consult factory for 50HZ operation.
6. Unit weight crated for shipment. Air-cooled units shipped in two units. Basic field assembly required for Air-cooled units.
7. Specifications are shown for a single unit. Some models use multiple condenser units. Field charging required.
8. Field installation including piping connection and charging of remote air-cooled condenser by owner. Process connections may vary based on unique pump flow
requirements of your process. Confirm you connection size requirement with your Advantage sales representative.
9. Vertical discharge from condenser.
10. Full load amperage shown for single condenser unit. Some models use multiple condenser units.
11. Unit weight crated for shipment.
12. See Warranty Statement #W-700 for details.