- Advantage BC & BCD Series air-cooled chillers use mechanical refrigeration to cool recirculated fluid that support industrial process cooling applications.
- Glycol chillers are configured to produce fluid temperatures between 25°-30°F using a mixture of water & glycol to prevent the fluid from freezing but can also be adjusted to produce fluid temperatures as low as 20°F and as high as 70°F.
- Air-cooled chillers use ambient air to dissipate the heat from the refrigeration system.
- BC-N4 & BCD-N4 models are designed for outdoor installation.
BGD-3A-N4- Refrigerant Zones
- Quantity : 1
- Capacity
- (2) BTH @ 25°F : 17,292
- (3) BTH @ 50°F : 36,000
- Compressor
- HP : 3
- Type : Single Digital Scroll
- Refrigerant
- Type : HFC-410A
- Air-Cooled Condenser
- # of Fans : 1
- Evaporator
- Type : Brazed Plate
- Process Pump
- (4) HP : 1.5
- (5) GPM : 10
- PSI : 42
- Reservoir Capacity
- Capacity : 7 gal
- Construction : Polyethylene
- Process Connection
- Size & Type : 1" NPT
- Dimensions (6)
- Height : 43"
- Width : 34"
- Length : 52"
- Controller
- Instrument Type : M1
- System Amperage (7)
- 230/3/60 : 28
- 230/1/60 : 41
- 460/3/60 : 12
- Specification Notes:
- 1. Since product innovation and improvement is our constant goal, all features and specifications are subject to change without notice or liability. Selection of certain optional features may change listed specifications.
- 2. Capacity at 25°F LFT and 115 °F condensing temperature. Capacities may be +/5% as reserved by the compressor manufacturer. The minimum recommended operating temperature when no glycol is used is 48°F.
- 3. Capacity at 50°F LFT and 115 °F condensing temperature. Capacities may be +/5% as reserved by the compressor manufacturer. The minimum recommended operating temperature when no glycol is used is 48°F.
- 4. Consult pump curve for exact pump performance.
- 5. Selection of optional pumps for higher flow rates will raise the minimum recommended operating temperature when no glycol is used.
- 6. Approximate dimensions. Not for construction purposes.
- 7. Full load amps are higher than run load amps and must be used for sizing disconnects and supply wiring. Not for construction. Consult factory for power requirements of unit as configured and on selected options.
- 8. See Product Warranty Statement W-700 for details on warranty.
- Refrigerant Circuit:
- Single Digital Scroll Compressor
- Compressor suction service valve
- Compressor discharge service valve
- Brazed Plate evaporator
- Integral air-cooled condenser
- with variable speed fans
- with pressure staging - Liquid receiver
- Liquid line solenoid valve
- Refrigerant sight glass with moisture indicator
- Thermostatic expansion valve
- Capacity control
- Non-Ozone depleting refrigerant
- Electrical:
- Outdoor rated electrical cabinet
- Fused transformer
- Fused pump motor starters
- Power entry terminal block
- Fused compressor motor starters
- Pressure Gauges:
- Refrigerant high pressure
- Refrigerant Low Pressure
- Coolant pressure
- Coolant Circuit:
- Large capacity process pump
- suction service valve
- discharge service valves - Polyethylene reservoir
- Reservoir Full Insulation
- Reservoir Drain Valve
- Reservoir Lid
- Warranty:
- 1 year covering parts and labor
- Warranty
- System Limit Devices:
- Refrigerant high pressure
- Refrigerant Low Pressure
- Instrument circuit fuse
- Pump motor overload
- Refrigerant Circuit
- Compressor Hour Meter
- Electrical
- Main power disconnect switch
- UL listed electrical panel
- Coolant Circuit
- Larger process pumps
- Overhead Piping Kit
- Warranty
- Extended compressor warranty
MG Series Control Instrument
- GRAPHIC LCD display with INTUITIVE NAVIGATION
- DIGITAL REFRIGERANT PRESSURE display
- DIGITAL WATER PRESSURE display
- Plain language error message reporting
- Controls hot gas bypass or digital scroll compressor for CAPACITY CONTROL
- ALARM OUTPUT with audible signal
- INDUSTRY 4.0 READY ... Modbus RTU or SPI communication included, Modbus TCP communication optional
- HIGH WATER TEMPERATURE shut down feature
Model BCD-3A-N4
Image is typical. Actual unit appearance will vary according to specifications and options.
-
Need Application Assistance?